Skip to main content

Table 3 Validity of airway assessment tests for predicting difficult intubations. Area under receiver operating characteristic curve of various airway assessment parameters

From: Evaluation of different airway tests to determine difficult intubation in apparently normal adult patients undergoing surgical procedures

 

MMT-TP

MMT-NTP

MPT

TMD

SMD

TP

6

9

7

7

8

FP

16

32

7

16

20

TN

129

113

138

129

125

FN

9

6

8

8

7

Accuracy %

84.38

76.25

90.63

85

83.1.3

Sensitivity %

40

60

46.67

46.67

53.33

Specificity %

88.97

77.93

95.17

88.97

86.20

PPV %

27.27

21.95

50

30.43

28.6

NPV %

93.48

94.96

94.52

94.16

94.7

Youden’s index

0.29

0.38

0.42

0.36

0.40

AUC

0.559

0.625

0.781

0.343

0.310

95% CI

0.407–0.710

0.493–0.757

0.655–0.907

0.198–0.488

0.170–0.451

  1. MMT-TP modified Mallampati test with tongue protrusion, MMT-NTP modified Mallampati test without tongue protrusion, MPT mandibular protrusion test, TMD thyromental distance, SMD sternomental distance, TP true positive, FP false positive, TN true negative, FN false negative, PPV positive predictive value, NPV negative predictive value, AUC area under curve, and CI confidence interval