Skip to main content

Table 1 Results from 13 operations performed with staff dressed in Mertex P-3477, Textilia AB with two TOUL devices

From: Comparison of three distinct clean air suits to decrease the bacterial load in the operating room: an observational study

Operation

Nr of persons in OR

Operation

CFU/m3

Measurements/excluded (reason)

Median

Mean

Min - Max

1

6

Uncemented THR

6.0

6.5

3–12

6/0

2

6

Cemented THR

55.0

63.8

23–100

7/1 (fluid on filter)

3

6

Cemented THR

23.0

22.7

15–30

7/1 (fluid on filter)

4

6

Cemented THR

33.0

43.4

21–100

7/2 (1 condensate, 1 damaged filter)

5

6

Cemented THR

8.0

18.5

7–18

7/3 (condensate)

6

6

Cemented THR

15.0

22.2

8–55

6/0

7

6

Cemented THR

8.0

10.8

6–20

6/1 (condensate)

8

6

Hybrid THR

46.0

61.3

23–148

7/0

9

6

Cemented THR

42.0

40.9

17–58

7/0

10

6

Cemented THR

24.0

24.9

12–40

7/0

11

6

Cemented THR

16.0

16.3

6–24

7/1 (condensate)

12

6

Uncemented THR

8.5

10.2

6–17

7/1 (damaged filter)

13

6

Cemented THR

13.0

12.7

1–28

7/0

  1. OR Operating Room, CRU Colony Forming Units, THR Total Hip Replacement