Skip to main content

Three-dimensional printing models increase inter-rater agreement for classification and treatment of proximal humerus fractures

Abstract

Background

Proximal humerus fractures (PHF) are frequent, however, several studies show low inter-rater agreement in the diagnosis and treatment of these injuries. Differences are usually related to the experience of the evaluators and/or the diagnostic methods used. This study was designed to investigate the hypothesis that shoulder surgeons and diagnostic imaging specialists using 3D printing models and shoulder CT scans in assessing proximal humerus fractures.

Methods

We obtained 75 tomographic exams of PHF to print three-dimensional models. After, two shoulder surgeons and two specialists in musculoskeletal imaging diagnostics analyzed CT scans and 3D models according to the Neer and AO/OTA group classification and suggested a treatment recommendation for each fracture based on the two diagnostic methods.

Results

The classification agreement for PHF using 3D printing models among the 4 specialists was moderate (global k = 0.470 and 0.544, respectively for AO/OTA and Neer classification) and higher than the CT classification agreement (global k = 0.436 and 0.464, respectively for AO/OTA and Neer). The inter-rater agreement between the two shoulder surgeons were substantial. For the AO/OTA classification, the inter-rater agreement using 3D printing models was higher (k = 0.700) than observed for CT (k = 0.631). For Neer classification,  inter-rater agreement with 3D models was similarly higher (k = 0.784) than CT images (k = 0.620). On the other hand, the inter-rater agreement between the two specialists in diagnostic imaging was moderate. In the AO/OTA classification, the agreement using CT was higher (k = 0.532) than using 3D printing models (k = 0.443), while for Neer classification, the agreement was similar for both 3D models (k = 0.478) and CT images (k = 0.421). Finally, the inter-rater agreement in the treatment of PHF by the 2 surgeons was higher for both classifications using 3D printing models (AO/OTA—k = 0.818 for 3D models and k = 0.537 for CT images). For Neer classification, we saw k = 0.727 for 3D printing models and k = 0.651 for CT images.

Conclusion

The insights from this diagnostic pilot study imply that for shoulder surgeons, 3D printing models improved the diagnostic agreement, especially the treatment indication for PHF compared to CT for both AO/OTA and Neer classifications On the other hand, for specialists in diagnostic imaging, the use of 3D printing models was similar to CT scans for diagnostic agreement using both classifications.

Trial registration

Brazil Platform under no. CAAE 12273519.7.0000.5505.

Introduction

Proximal humerus fractures (PHF) are frequent, affecting a significant number of adults and elderly victims due to trauma or falls. Its prevalence in hospital emergency care is substantial and corresponds to approximately 45% of humerus fractures and 5% of total fractures [12, 23, 29]. However, understanding these fractures and the best way to treat them remains unsettled between doctors and researchers [8, 9, 11, 22, 24, 25]..

Although PHF is relevant and is growing worldwide, controversies related to its diagnosis and treatment definitions are still frequent [8, 9, 11, 17, 22, 25]. The classifications proposed by Charles Neer [22] and the AO/OTA group—Arbeit Gemeinschaft für Osteosynthesefragen [17] are widespread and used worldwide. However, there is still no relevant reproducibility for the diagnosis and treatment of PHF [1, 3, 5,6,7, 10, 15, 21]..

This study presents 3D printing models of PHF as an alternative method for diagnosing and treating these injuries. These models, also called prototypes, are personalized and individualized prints reproducing three-dimensionally and faithfully the fractures' original characteristics. We believe that the 3D models created will help understanding the patterns of shoulder fractures, improving their classification and, consequently, the treatment.

Therefore, this work analyzes the inter-rater agreement and the interface between shoulder surgeons and specialists in musculoskeletal imaging, comparing computed tomography exams with 3D printing models.

Methods

We obtained 75 tomographies of fractures of the proximal humerus at random from an image database of Hospital Samaritano Higienópolis -Américas Serviços Médicos. There was no identification of the patients submitted to the exams, and confidentiality and anonymity were maintained throughout the study. We included tomographic images of fractures of the proximal humerus of both sexes, adults (physeal growth plate closure checked), attended at the Hospital with complete and good quality tomographic exams (sagittal, axial, and coronal sections). We did not include images related to pathological (neoplastic) fractures, infectious diseases (acute or chronic), pre-existing PHF or deformities, and congenital morphological changes.

The 75 selected tomographic images were used for three-dimensional printing models (prototypes) of the fractures, with a single piece corresponding to each image. The company DASA (Diagnósticos da América) executed the prints and donated them to the researchers. The pieces were printed in PLA (polyacid lactic), a synthetic thermoplastic polymer of biological origin, obtained by renewable resources, composed of starch or sugar such as corn, wheat, beet, or sugar cane. The models were printed in actual size, reproducing exclusively the bone characteristics of the fractures, with no inclusion of the scapula or clavicle (Figs. 1, 2 and 3). Complex fractures were not excluded to maintain the original characteristics of each case, however we do not include the scapula and clavicle in the three-dimensional models. The impressions would result in a unique model, making the scapulohumeral joint limits imprecise for three-dimensional analysis. Furthermore, the coverage of part of the humeral head by fusion in the glenoid would not allow the assessment of joint fractures, interfering in the classification and especially in the therapeutic indications. For this reason, we did not include images of fractures dislocations of the shoulder, so that parameters of joint inconsistencies were not considered by the experts.

Fig. 1
figure 1

3D printing models of proximal humerus fractures using CT scans as a model

Fig. 2
figure 2

3D printing models of proximal humerus fractures using CT scans as a model

Two orthopedists, specialists in shoulder surgery linked to the Shoulder and Elbow Sector of the Department of Orthopedics and Traumatology at Escola Paulista de Medicina (DOT/UNIFESP) and two doctors, specialized in musculoskeletal imaging diagnostics associated with the Department of Diagnostic Imaging at Escola Paulista de Medicina (DDI/UNIFESP), were invited to evaluate the exams. The four doctors had at least 5 years of experience in their respective areas. They did not participate in the selection of tomographic images from the database or in the 3D model printing. Before the beginning of the evaluations, the four experts participated in a theoretical review on the concepts of the adopted classifications and received the AO/OTA and Neer classifications sheets to be used or consulted during the procedure (Figs. 4 and 5).

Fig. 3
figure 3

Photograph of 75 samples of 3D printing models of proximal humerus fractures

Fig. 4
figure 4

AO/OTA classification for fractures of the proximal humerus. Obtained from Meinberg EG et al. (pS1-S10) [16]

The tomographic images and the 3D models were evaluated simultaneously by the four doctors at different times. The 75 tomographies were displayed sequentially on high-resolution screens, as axial, coronal, and sagittal complete sections, so that doctors could classify the fractures according to the AO/OTA classification. Later the specialists received each of the three-dimensional models corresponding to the tomographic images in sequential order. The prototypes were randomly delivered in relation to the previously presented tomography cases, so they could also be classified according to the AO/OTA classification. Then, the same protocol was followed, adopting the Neer classification. The Fig. 6 (case 35) exemplifies some correlations between 3D printing models and corresponding tomographic images to be compared.

Fig. 5
figure 5

Neer’s classification of proximal humeral fractures. Neer CS 2nd. Displaced proximal humeral fractures. Part I. Classification and evaluation. J Bone Joint Surg Am. 1970;52(6):1077–89 [21]

Fig. 6
figure 6

Case 35 of PHF with tomographic images and frontal (A), axial (B), and sagittal (C) sections. 3D models in frontal view (D), axial (E), and sagittal (F)

The evaluations were carried out using multiple-choice questionnaires and individualized by classification (Tables 1 and2 ).

The four specialists were responsible for classifying the fractures according to AO/OTA and Neer classification using the two diagnostic methods. However, only shoulder surgeons were asked to indicate any treatment for each case. The options were divided into two indications: non-surgical and surgical (osteosynthesis or shoulder arthroplasty). During the evaluation of the images, no information regarding clinical history, sex, age, upper limbs dominance, or the patients' possible associated diseases was disclosed. To maintain a correspondence between the AO/OTA and Neer classifications in relation to the number of parts (type A—AO/OTA equivalent to 2-parts of Neer, and types B and C—AO/OTA equivalent to 3- and 4-parts of Neer, respectively) as proposed by Meinberg et al [17], we excluded the AO/OTA classification subtypes in this study, maintaining the correspondence confidence that concordance studies require.

After two weeks, the same four specialists were invited to repeat the assessments, using similar protocol and conditions mentioned above for the same 75 cases, for results’ reproducibility.

Statistical analysis

We used a 95% confidence interval for the analysis with a sampling error of 0.07 for a Kappa concordance coefficient estimated at 0.50.For this calculation, a standard deviation of 0.30 was used [13]. For these calculations, we used the statistical software PASS 2008 (Power Analysis and Sample Size System)—NCSS.

The evaluation of inter-observer and intra-observer agreement was performed using Kappa coefficients. The overall Kappa coefficients were shown to classify the agreement between more than two observers. For all statistical tests, a significance level of 5% was used.

Statistical analyzes were performed using the statistical software SPSS 20.0 and STATA 12.

Results

Kappa coefficients between both classifications (AO/OTA and Neer), treatment indication, and diagnostic method are shown (Table 3). The inter-rater agreement for PHF using 3D printing models among the four specialists was moderate (overall k = 0.470 and 0.544, respectively for AO/ OTA and Neer classification), however, higher than CT (overall k = 0.436 and 0.464, respectively, for AO / OTA and Neer classification).

The classifications between the two shoulder surgeons were substantial. In the AO/OTA classification, the inter-rater agreement using 3D printing models was higher (k = 0.700) than seen for CT (k = 0.631). For Neer classification, inter-rater agreement with 3D models was higher (k = 0.784) than CT images (k = 0.620). Moreover, the inter-rater agreement between the two specialists in diagnostic imaging was moderate. In the AO/OTA classification, the  inter-rater agreement using CT was higher (k = 0.532) than using 3D printing models (k = 0.443). Using the Neer classification, the inter-rater agreement was similar for both 3D models (k = 0.478) and CT images (k = 0.421).

The two surgeons' inter-rater agreement for treatment indication of PHF was higher for both classifications using 3D printing models. In the AO/OTA classification, the inter-rater agreement for 3D models was k = 0.818 (almost perfect), while for CT was k = 0.537 (moderate). The Neer inter-rater agreement for treatment indication with 3D models was k = 0.727 and k = 0.651 for CT images (both were substantial).

Concordance between classification types (AO/OTA and Neer) by specialist and diagnostic method

In this analysis, the 68 images that did not obtain the classification as 1-part fracture in the Neer Classification were considered. In this way, it was possible to maintain the fracture’s correspondence between both classifications due to the absence of correspondence between the 1-part fractures for Neer and AO/OTA classifications [17].

As seen in Table 4, surgeons had a higher inter-rater agreement between AO/OTA and Neer classifications using 3D printing models than CT images. For the specialists in diagnostic imaging, the inter-rater agreement was similar for both 3D and CT.

Reproducibility between different periods of evaluation after a 15-day interval

There were substantial to almost perfect reproducibilities using CT images and 3D models (Kappa values ranged from 0.615 to 0.839, respectively) for both images’ classification and treatment indication (Table 5). Among specialists in diagnostic imaging, a moderate inter-rater agreement was seen for fractures classification using 3D printing models (Kappa values ranged from 0.410 to 0.459). On the other hand, for CT images, one specialist showed moderate and the other weak concordance.

Discussion

In this work, among surgeons, the association of 3D printing models and the AO/OTA and Neer classifications improved the intra- and inter-observer agreement for the diagnosis of PHF compared with CT scans. Moreover, as seen in a previous publication [1, 3, 5], treatment indication had the best inter-rater agreement between surgeons. On the other hand, among specialists in musculoskeletal imaging, 3D printing models and CT scans showed moderate inter-rater agreement between the diagnostic methods. The descriptive pattern of fractures for specialists in musculoskeletal imaging daily routine usually focuses on local anatomical characterization [16]. Moreover, they are unfamiliar with orthopedic classifications used by surgeons (AO/OTA and Neer), explaining the divergent results. We believe that treatment planning using 3D printing models facilitates surgeons' diagnosis when manipulating the bone fragments and implants' choice (size and models of plates or nails, and the number of screws). Besides, the surgeon can objectively understand bone imperfections that are frequent in fractures of the humerus. Surgeons are influenced by tactile rather than exclusively visual aspects of shoulder fractures. The manipulation of 3D models ends up stimulating reasoning and interpretation areas that may not be required by visual exams only, such as CT scans. Similar to 3D model manipulation, palpation of bone fragments are part of the surgical procedure for fracture pattern understanding. In this respect, only 3D printing models can reproduce this stimulus, explaining the higher inter-rater agreement obtained for treatment indication reported here.

Shoulder surgeons still diagnose and choose treatments based on their own experience and training, with weak evidence in most cases. Slings, plates, nails, and prostheses are present in their therapeutic arsenal to correlate the patient's characteristics, the fracture, and the surgeon's ability to use each one. On the other hand, specialists in imaging diagnosis have similar difficulties in diagnosing these fractures, either due to high lesion variability or the descriptive training in image interpreting. Also, they are unfamiliar with pre-existing classifications such as AO/OTA or Neer classification, unlike shoulder surgeons, leading to opinion and diagnostic divergences.

Although there is no gold standard for diagnosing PHF, radiographs and CT scans are widely used for initial evaluation. Radiographs are cheap and quick and may show patients' critical characteristics related to shoulder pain and after local trauma. However, positioning the patient with pain during examination impairs the diagnosis and the correct interpretation of the fracture. Thus, in clinical practice, tomography is widely used to assess and characterize the extent of shoulder fractures [2, 4, 18]. Besides, it is through these exams that information for treatment choice is observed.

In parallel with scientific development in the medical area, 3D models in the industrial and daily lives are frequent. 3D printers can turn palpable images previously imprisoned on screens increasingly popular in quality and costs. This area's evolution is also growing in the clinical and medical field scientific routine[27]. Research on the particularities of several fractures involving three-dimensional prototypes is growing, and the results stimulate more applications. In the orthopedic area, 3D models of fractures can improve the understanding of injuries' complexity among specialists and assist in educating doctors and professionals involved in the treatment of these diseases [14, 19, 20, 26,27,28, 30].

Among specialists in musculoskeletal imaging, 3D printing models and CT scans showed moderate inter-rater agreement between the diagnostic methods. Thus, grouping fractures within the proposed classifications may have been harder for them compared to surgeons. According to Mitsouras et al [19], the inter-rater agreement between different methods, the inclusion of 3D printing models in the professional routine of orthopedic classifications, and the possibility of accessing these models will bring an essential alternative for evaluating humerus fractures by specialists in diagnostic imaging.

Although 3D printing models are not yet considered an official diagnostic method, and may add costs and time (around US$ 30,00/each and 90 min for each printing) to the diagnostic process, they reproduce reliable prototypes from CT images. For the medical field, anatomical parts' characterization and the customization and optimization of resources can improve orthopedical diseases' diagnosis and treatment. In addition, the 3D models can be used for training and for educating doctors and health professionals. Our work shows these interfaces, improving the understanding of PHF treatment among specialists and surgeons.

However, we emphasize that although this study was designed to analyze the inter-rater agreement between 3D impression models, CT scans, classifications and experts, the lack of information related to sensitivity and specificity between the methods does not allow us to discuss a possible superiority between the exams. In addition, other limitations such as absence of patients clinical information, or excluding some patterns of shoulder fractures (fractures dislocations) may have influenced surgeons in the choice of treatment for each case presented.

Conclusions

For shoulder surgeons, 3D printing models improved the diagnostic, especially the inter-rater treatment indication agreement for PHF compared to CT scans for both AO/OTA and Neer classifications.

For specialists in diagnostic imaging, the use of 3D printing models was similar for diagnostic inter-rater agreement of PHF compared to CT for both AO/OTA and Neer classifications.

Table 1 Questionnaires for shoulder surgeons
Table 2 Questionnaires for diagnostic imaging specialists
Table 3 Kappa coefficient by type of classification, treatment indicated, and methods of diagnosis
Table 4 Kappa coefficient of agreement between classifications and diagnostic methods among specialists for proximal humerus fractures
Table 5 Reproducibility of Kappa coefficients between different periods of evaluation by type of classification, diagnostic methods, and between specialists. Interval of 15 days

Availability of data and materials

The datasets used and analysed during the current study are available from the corresponding.

The authors declare that this research was carried out in strict compliance with all methods in accordance with the relevant guidelines and regulations proposed to ensure that ethical and moral principles have been carefully adopted and obeyed, and that meet the values ​​and ideals proposed by the editorial board of this journal.

Abbreviations

PHF:

Proximal humerus fracture

AO/OTA:

Arbeit Gemeinschaft für Osteosynthesefragen group

DASA:

Diagnósticos da América

PLA:

Polyacid lactic

CT:

Computed tomography

DOT/UNIFESP:

Department of Orthopedics and Traumatology at Escola Paulista de Medicina

DDI/UNIFESP:

Department of Diagnostic Imaging at Escola Paulista de Medicina

PASS:

Power Analysis and Sample Size System

References

  1. Bougher H, Buttner P, Smith J, Banks J, Na HS, Forrestal D, et al. Interobserver and intraobserver agreement of three-dimensionally printed models for the classification of proximal humeral fractures. JSES Int. 2021;5(2):198–204 Available from: https://doi.org/10.1016/j.jseint.2020.10.019.

  2. Bougher H, Nagendiram A, Banks J, Hall LM, Heal C. Imaging to improve agreement for proximal humeral fracture classification in adult patient: A systematic review of quantitative studies. J Clin Orthop Trauma. 2020;11:S16–24 Available from: https://doi.org/10.1016/j.jcot.2019.06.019.

  3. Brorson S, Olsen BS, Frich LH, Jensen SL, Sørensen AK, Krogsgaard M, et al. Surgeons agree more on treatment recommendations than on classification of proximal humeral fractures. BMC Musculoskelet Disord. 2012;13. doi:https://doi.org/10.1186/1471-2474-13-114

  4. Brunner A, Honigmann P, Treumann T, Babst R. The impact of stereo-visualisation of three-dimensional CT datasets on the inter- and intraobserver reliability of the AO/OTA and Neer classifications in the assessment of fractures of the proximal humerus. J Bone Jt Surg - Ser B. 2009;91(6):766–71. https://doi.org/10.1302/0301-620X.91B6.22109.

    Article  CAS  Google Scholar 

  5. Cocco LF, Aihara AY, Franciozi C, Dos Reis FB, Luzo MVM. Three-dimensional models increase the interobserver agreement for the treatment of proximal humerus fractures. Patient Saf Surg. 2020;14(1):1–10. https://doi.org/10.1186/s13037-020-00258-2.

    Article  Google Scholar 

  6. Cocco LF, Ejnisman B, Belangero PS, Cohen M, dos Reis FB. Quality of life after antegrade intramedullary nail fixation of humeral fractures: A survey in a selected cohort of Brazilian patients. Patient Saf Surg. 2018;12(1):1–8. https://doi.org/10.1186/s13037-018-0150-8.

    Article  Google Scholar 

  7. Cocco LF, Yazzigi JA, Kawakami EFKI, Alvachian HJF, Dos Reis FB, Luzo MVM. Inter-observer reliability of alternative diagnostic methods for proximal humerus fractures: A comparison between attending surgeons and orthopedic residents in training. Patient Saf Surg. 2019;13(1):1–13. https://doi.org/10.1186/s13037-019-0195-3.

    Article  Google Scholar 

  8. Foroohar A, Tosti R, Richmond JM, Gaughan JP, Ilyas AM. Classification and treatment of proximal humerus fractures: Inter-observer reliability and agreement across imaging modalities and experience. J Orthop Surg Res. 2011. https://doi.org/10.1186/1749-799X-6-38.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Gracitelli MEC, Malavolta EA, Assunção JH, Kojima KE, dos Reis PR, Silva JS, et al. Locking intramedullary nails compared with locking plates for two- and three-part proximal humeral surgical neck fractures: A randomized controlled trial. J Shoulder Elb Surg. 2016;25(5):695–703. https://doi.org/10.1016/j.jse.2016.02.003. Available from: https://pubmed.ncbi.nlm.nih.gov/27085296/.

    Article  Google Scholar 

  10. Gumina S, Giannicola G, Albino P, Passaretti D, Cinotti G, Postacchini F. Comparison between two classifications of humeral head fractures: Neer and AO-ASIF. Acta Orthop Belg. 2011;77(6):751–7. Available from: https://pubmed.ncbi.nlm.nih.gov/22308619/.

    PubMed  Google Scholar 

  11. Handoll H, Gibson J, Madhok R. Interventions for treating proximal humeral fractures in adults: Review. Cochrane Libr. 2008;4:1–3.

    Google Scholar 

  12. Jabran A, Peach C, Ren L. Biomechanical analysis of plate systems for proximal humerus fractures: A systematic literature review. Biomed Eng Online. 2018;17(1):1–31 Available from: https://doi.org/10.1186/s12938-018-0479-3.

  13. Landis JR, Koch GG. The Measurement of Observer Agreement for Categorical Data. Biometrics. 1977;33(1):159. https://doi.org/10.2307/2529310.

    Article  CAS  PubMed  Google Scholar 

  14. Laverdiere C, Harvey E, Schupbach J, Boily M, Burman M, Martineau PA. Effect of Teaching Session on Resident Ability to Identify Anatomic Landmarks and Anterior Cruciate Ligament Footprint: A Study Using 3-Dimensional Modeling. Orthop J Sport Med. 2020;8(3):1–9. https://doi.org/10.1177/2325967120905795.

    Article  Google Scholar 

  15. Marongiu G, Leinardi L, Congia S, Frigau L, Mola F, Capone A. Reliability and reproducibility of the new AO/OTA 2018 classification system for proximal humeral fractures: a comparison of three different classification systems. J Orthop Traumatol. 2020;21(1):4 Available from: https://doi.org/10.1186/s10195-020-0543-1.

  16. Martin JS, Marsh JL. Current classification of fractures. Rationale and utility. Radiol Clin North Am. 1997;35(3):491–506.

    CAS  PubMed  Google Scholar 

  17. Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and Dislocation Classification Compendium-2018. J Orthop Trauma. 2018;32:S1–170. https://doi.org/10.1097/BOT.0000000000001063. Available from: https://journals.lww.com/jorthotrauma/Fulltext/2018/01001/Fracture_and_Dislocation_Classification.1.aspx.

    Article  PubMed  Google Scholar 

  18. Meleán P, Munjin A, Pérez A, Rojas JT, Cook E, Fritis N. Coronal displacement in proximal humeral fractures: correlation between shoulder radiographic and computed tomography scan measurements. J Shoulder Elb Surg. 2017;26(1):56–61. Available from: https://pubmed.ncbi.nlm.nih.gov/27521137/https://doi.org/10.1016/j.jse.2016.05.016.

  19. Mitsouras D, Liacouras P, Imanzadeh A, Giannopoulos AA, Cai T, Kumamaru KK, et al. Medical 3D printing for the radiologist. Radiographics. 2015;35(7):1965–88. https://doi.org/10.1148/rg.2015140320.

    Article  PubMed  Google Scholar 

  20. Mulford J, MacKay N, Babazadeh S. Three Dimensional Printing in Orthopaedic Surgery. Orthop J Sport Med. 2016;4(2):2325967116S0002. https://doi.org/10.1177/2325967116s00022.

    Article  Google Scholar 

  21. Murray IR, Amin AK, White TO, Robinson CM. Proximal humeral fractures: Current concepts in classification, treatment and outcomes. J Bone Jt Surg Ser B. 2011;93(1):1–11. https://doi.org/10.1302/0301-620X.93B1.25702.

    Article  CAS  Google Scholar 

  22. Neer CS. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am. 1970;52(6):1077–89. https://doi.org/10.2106/00004623-197052060-00001.

    Article  PubMed  Google Scholar 

  23. Passaretti D, Candela V, Sessa P, Gumina S. Epidemiology of proximal humeral fractures: a detailed survey of 711 patients in a metropolitan area. J Shoulder Elb Surg. 2017;26(12):2117–24. https://doi.org/10.1016/j.jse.2017.05.029. Available from: https://pubmed.ncbi.nlm.nih.gov/28735839/.

    Article  Google Scholar 

  24. Roy JS, BraÃn C, Leblond J, Desmeules F, Dionne CE, MacDermid JC, et al. Diagnostic accuracy of ultrasonography, MRI and MR arthrography in the characterisation of rotator cuff disorders: A systematic review and meta-analysis. Br J Sports Med. 2015;49(20):1316–28. https://doi.org/10.1136/bjsports-2014-094148.

    Article  PubMed  Google Scholar 

  25. Russo R, Guastafierro A, della Rotonda G, Viglione S, Ciccarelli M, Mortellaro M, et al. A new classification of impacted proximal humerus fractures based on the morpho-volumetric evaluation of humeral head bone loss with a 3D model. J Shoulder Elb Surg. 2020;29(10):e374–85. https://doi.org/10.1016/j.jse.2020.02.022. Available from: http://www.jshoulderelbow.org/article/S1058274620302330/fulltext.

    Article  Google Scholar 

  26. Sallent A, Vicente M, Reverté MM, Lopez A, Rodríguez-Baeza A, Pérez-Domínguez M, et al. How 3D patient-specific instruments improve accuracy of pelvic bone tumour resection in a cadaveric study. Bone Jt Res. 2017;6(10):577–83. https://doi.org/10.1302/2046-3758.610.BJR-2017-0094.R1.

    Article  CAS  Google Scholar 

  27. Tack P, Victor J, Gemmel P, Annemans L. 3D-printing techniques in a medical setting: A systematic literature review. Biomed Eng Online. 2016;15(1):1–22. https://doi.org/10.1186/s12938-016-0236-4.

    Article  Google Scholar 

  28. Yao X, Zhou K, Lv B, Wang L, Xie J, Fu X, et al. 3D mapping and classification of tibial plateau fractures. Bone Jt Res. 2020;9(6):258–67. https://doi.org/10.1302/2046-3758.96.BJR-2019-0382.R2.

    Article  Google Scholar 

  29. Ye Y, You W, Zhu W, Cui J, Chen K, Wang D. The Applications of Finite Element Analysis in Proximal Humeral Fractures. Comput Math Methods Med. 2017;2017:4879836. https://doi.org/10.1155/2017/4879836.

    Article  PubMed  PubMed Central  Google Scholar 

  30. You W, Liu LJ, Chen HX, Xiong JY, Wang DM, Huang JH, et al. Application of 3D printing technology on the treatment of complex proximal humeral fractures (Neer3-part and 4-part) in old people. Orthop Traumatol Surg Res. 2016;102(7):897–903. https://doi.org/10.1016/j.otsr.2016.06.009. Available from: https://pubmed.ncbi.nlm.nih.gov/27521179/.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

This study received academic support by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES) – Finance Code 001. To the specialists who dedicated themselves to the evaluation of the cases. DASA (Diagnósticos da América) for donating three-dimensional printing models. Hospital Samaritano Higienópolis (Americas Serviços Médicos). Escola Paulista de Medicina/Universidade Federal de São Paulo, Departments of Orthopedics and Diagnostic Imaging

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

LFC: Study conceptualization, paper wrinting, supervision during the analysis of 3D models and CT scans by specialists AYA: Statistical analysis FPPLL: three-dimensional models acquisition HW: three-dimensional models acquisition CF: Paper writing FBR: Statistical analysis MVML: Paper writing, final revision. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Luiz Fernando Cocco.

Ethics declarations

Ethics approval and consent to participate

All participants who were included in the research adhered and spontaneously signed the written informed consent form proposed for this research, as requested by the Ethics Committee. The project was reviewed and approved by the same responsible local Ethics Committee and the study was registered in the Brazil Platform under no. CAAE 12273519.7.0000.5505.

Consent for publication

Not applicable.

Author on reasonable request.

Competing interests

All authors declare, that they have no conflict of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cocco, L.F., Aihara, A.Y., Lopes, F.P.P.L. et al. Three-dimensional printing models increase inter-rater agreement for classification and treatment of proximal humerus fractures. Patient Saf Surg 16, 5 (2022). https://doi.org/10.1186/s13037-021-00312-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13037-021-00312-7

Keywords