Increased CO2 levels in the operating room correlate with the number of healthcare workers present: an imperative for intentional crowd control

Abstract

The air in an operating room becomes more contaminated as the occupancy of the room increases. Individuals residing in a room can potentially emit infectious agents. In order to inhibit and better understand the epidemiology of surgical site infections, it is important to develop procedures to track room occupancy level and respiration. Exhaled CO2 provides a respiratory byproduct that can be tracked with IR light and is associated with human occupancy. Exhaled CO2 can also be used as an indirect measure of the potential release and level of infectious airborne agents. We show that non-dispersive infrared CO2 sensors can be used to detect CO2 in operating room air flow conditions of 20 air changes per hour and a positive pressure of 0.03 in. H2O. The CO2 concentration increased consecutively for occupation levels of one to four individuals, from approximately 65 ppm above the background level when one individual occupied the operating room for twenty minutes to approximately 300 ppm above the background when four individuals were present for twenty minutes. The amount of CO2 detected increases as the number of occupants increase, the activity level increases, the residency time increases and when the ventilation level is reduced.

Introduction

In-door air quality is affected by a variety of factors including human occupation [1,2,3]. Developing and applying effective and non-invasive methods that monitor the amount of people in a room is particularly important in clinical settings where air quality is a major factor that can contribute to nosocomial infection including surgical site infections [4, 5]. It has been reported that 2.0-2.4% of all total joint arthroplasties in the U.S. result in periprosthetic infection [6], which imposes significant morbidity on patients and large financial burdens on the healthcare system [7], making the pursuit of improved air quality in operating rooms of high importance. In general, the quality of the air in an operating room (OR) will be compromised by various viable and non-viable particulate matter and small molecules as the number of people in the room increases [8]. For example, bioaerosols are emitted into the surrounding environment as people breathe, talk, laugh, cough or sneeze [9]. Additionally, human skin sheds squamous epithelial cells which can contain micro-organisms [10]. A promising strategy for enhancing OR environment management involves the application of automated sensors to track the flow of human traffic and respiration over time. It is well-known that occupants contribute to the concentration of indoor CO2 [11,12,13]. Carbon dioxide (CO2) provides a detectable marker of respiration that can be routinely monitored and is expected to increase in concentration in an indoor environment as more individuals occupy a room or building (Fig. 1). CO2 emissions from individuals under various activity levels and environmental conditions is an active area of research. Recent studies have investigated the effect of various conditions including sedentary vs active behavior, indoor pollutants, ambient CO2 levels, stressed vs relaxed cognitive activities, metabolic rate, temperature, gender and age [14,15,16,17,18,19,20,21]. Measurement of CO2 concentration has previously been suggested as a tool for estimating airborne infection transmission risk [22]. Recently, analytical expressions were derived for the probability of Covid-19 infection based on CO2 levels in a number of indoor environments [23]. However, little data is available on the behavior and detectability of occupant-driven CO2 levels in the operating room environment.

Fig. 1
figure 1

Exhalation produces CO2. CO2 accumulates in the air of an occupied operating room. As more individuals populate the room, the rate of CO2 accumulation in the room increases

CO2 exists in a gaseous state under ambient conditions and is a by-product of respiration. The respiration rate of a healthy adult is approximately 14-18 respirations per minute and the tidal volume of air associated with breathing is approximately 0.5 L [24]. Exhalation expels CO2 in an amount that is approximately 5% of the total volume of gas released. The amount of CO2 expelled by a healthy adult at rest is approximately 0.35–0.45 L/min. On average, an adult will release about 1.0 kg (580 L at 1 atm and 25º C) of CO2 per day. CO2 is generated during metabolism at a rate that is dependent on the physical activity of the individual. Higher levels of exhaled CO2 are associated with the production of higher levels of bioaerosols as both are byproducts of breathing. Heightened levels of bioaerosols increase the risk of infection for both patients and staff in an OR. High levels of CO2 in a room are also associated with discomfort and reduced cognitive abilities [25,26,27,28,29]. Understanding how the level of CO2 correlates with the number of occupants in an OR and incorporating CO2 sensing devices into clinical settings will provide significant insight into assessing factors that lead to post-operative wound infections [30].

CO2 detectors are readily available from a large number of manufacturers. While they have been used in a variety of environments, their utility in an OR would be clearer if carefully assessed in a controlled OR environment. Electrochemical gas sensors are subject to false readings from interfering gases. In comparison, NDIR (non-dispersive infrared) gas sensors [31, 32] are advantageous in that the readings are not affected by the presence of other gases as the characteristic IR absorption band of CO2 at approximately 2350 cm-1 (4.26 mm) does not overlap with common gases. Note that CO shows absorption maxima between 2100 and 2200 cm-1, which provides sufficient spacing to distinguish CO2 from CO. Additionally, NDIR sensors last longer and do not lose accuracy over time, whereas electrochemical sensors have a reduced shelf-life and wear out more quickly with usage as the electrolyte is consumed. Temperature and humidity can also reduce an electrochemical sensor’s lifetime. Importantly, NDIR sensors can measure CO2 concentrations below the ambient outdoor level of 400 ppm, whereas metal-oxide semiconductor-based sensors (a type of commercially available electrochemical sensor) generally have a lower limit of 2000 ppm, which is well above common ambient levels and therefore likely not suitable for measuring room occupation when few people are present [33]. While photoacoustic IR sensors that utilize micro-electromechanical systems technology appear to be exceptionally reliable, they are expensive relative to NDIR sensors and can cost over $40000 for one unit.

In this study, we examine the behavior of CO2 levels relative to the number of people and activity level in a simulated OR environment. We show that as the number of people in the room increases, the CO2 sensor detects a higher level of CO2 in the air (measured in ppm). The sensor used is sensitive enough to detect a single active individual in an enclosed OR with air circulation conditions of 20 air changes per hour (ACH) and positive pressure, which meets the ventilation requirements for an OR according to the American Society of Heating, Refrigeration and Air-Conditioning Engineers specification ASHRAE 170–2017. The performance demonstrated will facilitate selection of available technologies for use in future experiments and more complex systems for monitoring occupation level. The results provide fundamental data regarding CO2 accumulation in an OR that healthcare professionals can use to assess CO2 detection as a means to better understand and manage the occupation level and accumulative respiration in surgical environments. Awareness of occupation levels on air quality will encourage new and effective approaches to risk management strategies for minimizing surgical site infections. Note that while we focus on occupation level, it is also important to track the accumulation of respiratory byproducts which can contain harmful bioaerosols. While infectious agents might be difficult to detect, monitoring the changes in CO2 concentration provides a detectable proxy that can indicate if the byproducts of breathing are able to accumulate despite the presence of heavy air flow and positive pressure. We show that the CO2 level can accumulate as an individual breathes in an enclosed well-ventilated OR and that the CO2 concentration is dependent on the number of people in the room, which indicates that the relative contamination level of the air in an OR increases as people enter the room, even at standard OR ACH levels and positive pressure.

Methods

Testing was performed in a 50 m3 operating room simulator, which included central ceiling-mounted ducts directing HEPA-filtered supply air and four lower wall mounted air return ducts. The system supplied 20 air exchanges per hour (ACH) and 0.03 in. H2O (7.5 Pa) of positive pressure to the outside environment. The room was equipped with typical OR air flow obstructions including surgical lights, tables and medical equipment (Fig. 1). Two calibrated Aeroqual 500 NDIR CO2 sensors (Gas Sensing) were used to measure the concentration of CO2. This sensing device can measure CO2 concentrations in the range of 0-5000 ppm with a resolution of 1 ppm. All measurements were performed at ambient temperature. Data was collected electronically and downloaded to an external computer for analysis using Aeroqual Series S500 Monitor Software V6.5 and Microsoft Excel. The sensors were placed in the perimeter of the OR because the perimeter is more contaminated than the center. The first sensor was placed approximately 58 cm from a wall containing the entry/exit door. The sensor was approximately 2.4 m from the door and approximately 1.8 m from the head of an operating bed in the middle of the room. The second sensor was placed approximately 58 cm from the opposite wall and approximately 2.4 m from the head of the operating bed and approximately 5.3 m from the door. The two sensors were approximately 4.6 m apart. Sensor readings were taken at 60 s intervals. For occupancy data, adults walked in the room for 20 minutes at a moderate pace in a circular path, changing direction every 5 minutes. The door was kept closed during the experiments. For occupancy data, the change in CO2 immediately before entering the room was compared to the CO2 concentration upon exit. For three-hour single occupancy experiments, an adult rested in a chair for the first hour of occupancy, walked in the room for 1 hour at a moderate pace in a circular path, changing direction every 5 minutes, and rested in the chair for the final hour.

Results and discussion

In order to understand the sensitivity of our sensor to human respiration in an enclosed room, we initially monitored the change in CO2 concentration when one adult human resides in a simulated OR at ambient pressure and without ventilation. Two sensors were placed near opposite walls in the room in order to understand whether or not large spatiotemporal fluctuations in CO2 concentration develop. The CO2 level as a function of time for a representative trial is shown in Fig. 2 (sensor 2 data shown; see supporting information S1 for sensor 1 and subsequent trials data). Prior to entry, the background level of CO2 in the room was relatively constant, fluctuating around 525 ppm. After the individual entered the room and assumed a resting position seated in a chair, the CO2 level increased by approximately 200 ppm over a period of 1 hour. After 1 hour at rest, the individual stood up and walked in a circular path around the OR for 1 hour, reversing direction every 5 minutes. The increased activity level produced a faster rate of CO2 accumulation in the enclosed room, increasing by 350 ppm after 1 hour. After 1 hour of pacing the OR, the individual re-assumed the initial resting position. The CO2 level continued to rise, but at a reduced rate compared to the first and second hours in the OR, increasing by 156 ppm after 1 hour and bringing the total concentration to approximately 1259 ppm, which is approximately 2.4 times the initial background level. The individual then left the room, closing the door after exiting. The CO2 level remained relatively constant while uninhabited. After monitoring the CO2 level in the empty room for 1 hour, the door was propped open. The CO2 level rapidly reduced as the door remained open. Replication of the experiment multiple times showed consistency in the total change and rate of change in CO2 concentration for both sensors (See S1, S2, S3, S4 and S5).

Fig. 2
figure 2

When an individual enters an enclosed room, the amount of detectable CO2 increases with occupation time. The rate of CO2 increase is dependent on the activity level of the individual. The CO2 increases more quickly when the individual paces the room compared to when the individual is at rest. The slopes are compared for the active and at rest conditions for the individual in the enclosed and non-ventilated room

The average change in CO2 concentration and average slope for each of the three hours spent in the room are shown in the bar graph on the right in Fig. 2. The rate of CO2 accumulation consistently increases when the individual transitions from a resting state to moderate activity, and consistently decreases when the individual re-assumes a resting state. The average slopes for the initial resting phase (At Rest I), the active phase (Pacing) and the second resting phase (At Rest II) are 3.8 ± 0.3 ppm/min., 6.4 ± 0.5 ppm/min. and 2.4 ± 0.1 ppm/min, respectively. The average change in CO2 for the corresponding phases are 190 ± 10 ppm, 390 ± 30 ppm and 150 ± 7 ppm, respectively. The results show that a single individual can considerably increase the concentration of CO2 in a room and, by extension, affect the quality of the air. Importantly, an individual’s contribution to the CO2 level in a room can be reliably detected with a portable NDIR sensor and the rate of increase corresponds to the occupant’s activity level. Higher activity increases metabolic rate which in turn increases CO2 production. A recent study has similarly concluded that measured CO2 generation rates are positively associated with physical activity levels [18]. In all trials the CO2 level did not exceed 1400 ppm, which is below the Occupational Safety and Health Administration (OSHA) permissible exposure limit of 5000 ppm (averaged over 8 hours), however, the need for awareness is apparent. As noted above, a growing body of cross-disciplinary literature in fields that include cognitive psychology, indoor air quality and neuroscience suggests that increasing CO2 concentrations can impair cognitive function. For example, Allen et al. [25] reported declines in “cognitive function scores” when indoor CO2 levels were increased from approximately 500 ppm to approximately 950 ppm, and greater declines when the CO2 level was raised to approximately 1400 ppm. Activities that involve increasing amounts of time and/or number of people in an enclosed space with limited ventilation could produce CO2 levels above permissible limits or exceed levels associated with compromised cognitive performance.

In order to understand if metabolic CO2 production can be detected in an OR operating at standard conditions, we repeated the experiment under standard OR airflow conditions. The room ventilation operated at 20 air changes per hour (ACH) with a positive room pressure of 0.03 in. H2O. Figure 3 shows the CO2 concentration as a function of time for an individual in the enclosed OR. When at rest, it is very difficult to detect occupancy due to the air flow conditions. When the individual begins to walk in the room as described above, the CO2 level increases with time. After one hour of walking the maximum change detected was approximately 73 ppm. Similar results were obtained with the additional sensor in the room (see S6). This result shows that while the air circulation system and positive pressure have a beneficial effect on the air quality, it does not completely eliminate the respiratory influence on the air composition. The metabolic CO2 production of a single person can be detected even with standard OR air flow conditions, indicating that the exhalation products of one person can accumulate at a rate that is higher than its displacement by the ventilation system.

Fig. 3
figure 3

When an individual enters an enclosed room containing normal OR air flow conditions (positive pressure of 0.03 in. H2O and a ventilation system operating at 20 ACH), CO2 exhalation can be detected provided that the individual is moderately active. When a single person paces the OR for 1 h, the amount of CO2 in the room increases by up to approximately 73 ppm. When the active individual becomes seated and performs no physical activity the CO2 level decreases

In order to understand if the CO2 level increases with the number of individuals in an OR, we monitored the CO2 level when occupied by a pre-selected number of individuals for a period of 20 minutes under normal OR air flow conditions. Figure 4 shows a graph of change in CO2 level as a function of time for different quantities of occupants. The presence of a single individual pacing the room produces a clear rise in CO2 concentration. After repeating the experiment three times the average increase for sensors 1 and 2 show accumulations of approximately 54 ± 7 ppm and 59 ± 9 ppm, respectively. After exiting and ensuring that the door was closed, the detected CO2 concentration briefly increases before showing a long-term attenuation to the baseline level as shown by the representative trace in Fig. 4. As the number of occupants in the room increases, the CO2 level increases. When four occupants pace the room for 20 minutes, the CO2 level increases by 290 ppm. When three and two occupants pace the room for 20 minutes, the respective CO2 concentrations are 181 and 145 ppm. A graph on the right in Fig. 4 displays the change in CO2 concentration as a function of the number of occupants that were in the room. Under the conditions employed, the CO2 rises in a linear fashion. These results show that as the number of people in a room increases, the CO2 concentration increases, even under air purifying ventilation standards that are encountered in an OR. Note that the levels of CO2 obtained will vary with individuals, activity levels and ventilation rates, however, our data shows a clear trend indicating that higher CO2 levels are detected when the number of occupants in a room increases. A difference of one person is enough to detect a change in CO2 concentration.

Fig. 4
figure 4

The amount of detected CO2 increases over a 20-minute period when individuals are present in an OR with an air circulation system operating at a level of approximately 20 ACH and a positive pressure of 0.03 in. H2O (left). As the number of individuals in the room increases, the amount of detected CO2 increases. Upon exit, the CO2 level rapidly decreases. A graph showing the change in the level of CO2 as a function of the number of occupants is presented on the right. Data shown are for sensor 2. See S7 for sensor 1 data

In order to minimize surgical site infections, it is important to maintain clean air in an OR. Individuals introduce a number of viable and non-viable impurities to the air in an OR through various mechanisms including shedding, displacing particulate matter at rest on a surface and breathing, the latter of which produces CO2 [34,35,36,37]. We have demonstrated that changes in CO2 concentration provide a biomarker of human presence that can be detected even under air flow conditions of 20 ACH and positive pressure. Tracking CO2 level in an OR can help manage human traffic and facilitate the epidemiology of surgical site infections. Although well-managed ORs are ventilated and in many cases under positive pressure, our results show that the presence of one breathing individual creates detectable changes in the composition of the air in a properly ventilated OR. While at relatively low concentrations CO2 itself is benign, it provides a proxy for more harmful substances that are emitted via expiration, including the highly disruptive SARS-CoV-2 which causes COVID-19 [23]. Additionally, a number of health effects associated with rising CO2 levels in an enclosed space include drowsiness, loss of concentration, nausea, headaches and more severe consequences associated with oxygen deprivation as higher concentrations are reached [38]. Gaining an awareness and understanding of the effect of occupancy time and population on the CO2 concentration in an OR will facilitate public health risk management and spur the development of new technologies for using CO2 to track the occupancy and respiratory history of an OR during surgery. In combination with good ventilation, particle filtration, PPE and UV disinfection, CO2 monitoring can be employed in the toolbox of techniques used to manage, assess and prevent hospital acquired infections.

Conclusion

We have shown that the concentration of CO2 in an enclosed operating room increases as the room is populated. While the magnitude of increase is lower when the room is well-ventilated with positive pressure, the accumulation of CO2 over time reaches detectable levels and was shown to increase as more individuals occupied the room for a given amount of time. This study has important implications for developing systems for monitoring CO2 accumulation as well as building awareness for the involuntary and unavoidable contamination of the air in ORs upon human entry. Monitoring CO2 levels in an OR will provide critical information that can help mitigate risks that can lead to transmission of infections.

Availability of data and materials

All data generated and analyzed in this study are included in this publication and the supporting information file.

Abbreviations

CO2 :

Carbon dioxide

OR:

Operating room

SSI:

Surgical site infection

References

  1. Mandal J, Brandl H. Bioaerosols in Indoor Environment - A Review with Special Reference to Residential and Occupational Locations. Open Environ Monit J. 2011;4:83.

    Google Scholar 

  2. Napoli C, Marcotrigiano V, Montagna MT. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres. BMC Public Health. 2012;12:594.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Chatoutsidou SE, Serfozo N, Glytsos T, Lazaridis M. Multi-zone measurement of particle concentrations in a HVAC building with massive printer emissions: influence of human occupation and particle transport indoors. Air Qual Atmos Health. 2017;10:679–93.

    Article  CAS  Google Scholar 

  4. Pereira M, Tribess A, Buonanno G, Stabile L, Scungio M, Baffo I. Particle and Carbon Dioxide Concentration Levels in a Surgical Room Conditioned with a Window/Wall Air-Conditioning System. Int J of Environ Res Public Health. 2020;17:1180.

    Article  CAS  Google Scholar 

  5. Parvizi J, Barnes S, Shohat N, Edmiston CE. Environment of care: Is it time to reassess microbial contamination of the operating room air as a risk factor for surgical site infection in total joint arthroplasty? Am J Infect Control. 2017;45:1267–72.

    Article  PubMed  Google Scholar 

  6. Cook TM, Piatt CJ, Barnes S, Edmiston CE. The Impact of Supplemental Intraoperative Air Decontamination on the Outcome of Total Joint Arthroplasty: A Pilot Analysis. J Arthoplasty. 2019;34:549–53.

    Article  Google Scholar 

  7. Kapadia BH, McElroy MJ, Issa K, Johnson AJ, Bozic KJ, Mont MA. The economic impact of periprosthetic infections following total knee arthroplasty at a specialized tertiary-care center. J Arthoplasty. 2014;29:929–32.

    Article  Google Scholar 

  8. Obard JP, Fang LS. Airborne Concentrations of Bacteria in a Hospital Environment in Singapore. Water Air Soil Pollut. 2003;144:333–41.

    Article  Google Scholar 

  9. Tang JW, Noakes CJ, Nielsen PV, Eames I, Nicolle A, Li Y, Settles GS. Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: an overview of approaches. J Hosp Infect. 2011;77:213.

    Article  CAS  PubMed  Google Scholar 

  10. Percival SL, Emanuel C, Cutting KF, Williams DW. Microbiology of the skin and the role of biofilms in infection. Int Wound J. 2012;9:14–32.

    Article  PubMed  Google Scholar 

  11. Wargocki P. What we know and should know about ventilation. REHVA J. 2021;58:5–13.

    Google Scholar 

  12. Turel I Occupant-generated CO2 as an Indicator of Ventilation Rate, Lawrence Berkeley National Laboratory, 1980, retrieved from https://escholarship.org/uc/item/70r2g8kq.

  13. Korsavi SS, Montazami A, Mumovic D. Indoor Air Quality (IAQ) in Naturally- Ventilated Primary Schools in the UK: Occupant-Related Factors. Build Environ. 2020;180:106992.

    Article  Google Scholar 

  14. Sakamoto M, Li M, Kuga K, Ito K, Beko G, Williams J, Wargocki P. CO2 emission rates from sedentary subjects under controlled laboratory conditions. Build Environ. 2021;211:108735.

    Article  Google Scholar 

  15. Qi MW, Li XF, Weschler LB, Sundell J. CO2 generation rate in Chinese people. Indoor Air. 2014;24:559–66.

    Article  CAS  PubMed  Google Scholar 

  16. Kuga K, Ito K, Wargocki P. The effects of warmth and CO2 concentration, with and without bioeffluents, on the emission of CO2 by occupants and physiological responses. Indoor Air. 2021;31:2176–87.

    Article  CAS  PubMed  Google Scholar 

  17. Zhai Y, Li M, Gao S, Yang L, Zhang H, Arens E, Gao Y. Indirect calorimetry on the metabolic rate of sitting, standing and walking office activities. Build Environ. 2018;145:77–84.

    Article  Google Scholar 

  18. Yang L, Wang X, Li M, Zhou X, Liu S, Zhang H, Arens E, Zhai Y. Carbon dioxide generation rates of different age and gender under various activity levels. Build Environ. 2020;186:107317.

    Article  Google Scholar 

  19. Gall ET, Mishra AK, Li J, Schiavon S, Laguerre A. Impact of cognitive tasks on CO2 and isoprene emissions from humans. Environ Sci Technol. 2020;55:139–48.

    Article  PubMed  Google Scholar 

  20. Nomoto A, Hisayama R, Yoda S, Akimoto M, Ogata M, Tsutsumi H, Tanabe S. Indirect calorimetry of metabolic rate in college-age Japanese subjects during various office activities. Build Environ. 2021;199:107909.

    Article  Google Scholar 

  21. Persily A, de Jonge L. Carbon dioxide generation rates for building occupants. Indoor Air. 2017;27:868–79.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  22. Rudnick SN, Milton DK. Risk of indoor airborne infection transmission estimated from carbon dioxide concentration. Indoor Air. 2003;13:237–45.

    Article  CAS  PubMed  Google Scholar 

  23. Peng Z, Jimenez JL. Exhaled CO2 as a Covid-19 Infection Risk Proxy for Different Indoor Environments and Activities. Environ Sci Technol Lett. 2021;8:392–7.

    Article  CAS  Google Scholar 

  24. Tortora GJ, Anagnostakos NP. Principles of Anatomy and Physiology. 3rd ed. New York: Harper & Row Publishers; 1981.

    Google Scholar 

  25. Allen JG, MacNaughton P, Satish U, Santanam S, Vallarino J, Spengler JD. Associations of cognitive function scores with carbon dioxide, ventilation, and volatile organic compound exposures in office workers: A controlled exposure study of green and conventional office environments. Environ Health Perspect. 2016;124:805–12.

    Article  CAS  PubMed  Google Scholar 

  26. Harter M. Effects of carbon dioxide on the alpha frequency and reaction time in humans. Electroencephalogr Clin Neurophysiol. 1967;23:561–3.

    Article  CAS  PubMed  Google Scholar 

  27. Sayers JA, Smith RE, Holland RL, Keatinge WR. Effects of carbon dioxide on mental performance. J Appl Physiol. 1987;63:25–30.

    Article  CAS  PubMed  Google Scholar 

  28. Wargocki P, Porras-Salazar JA, Contreras‐Espinoza S, Bahnfleth W. The relationships between classroom air quality and children’s performance in school. Build Environ. 2020;173:106749.

    Article  Google Scholar 

  29. Du B, Tandoc MC, Mack ML, Siegel JA. Indoor CO2 concentrations and cognitive function: A critical review. Indoor Air. 2020;30:1067–82.

    Article  CAS  PubMed  Google Scholar 

  30. Karthikeyan CP, Samuel AA. CO2 dispersion studies in an operating theatre under transient conditions. Energy Build. 2008;40:231.

    Article  Google Scholar 

  31. Martin CR, Zeng N, Karion A, Dickerson RR, Ren X, Turpie BN, Weber KJ. Evaluation and environmental correction of ambient CO2 measurements from a low-cost NDIR sensor. Atmos Meas Tech. 2017;10:2383–95.

    Article  CAS  Google Scholar 

  32. Yasuda T, Yonemura S, Tani A. Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device. Sensors. 2012;12:3641.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  33. Fine GF, Cavanagh LM, Afonja A, Binions R. Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring. Sensors. 2010;10:5469.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  34. Noble WC, Habbema JDF, van Furth R, Smith I, de Raay C. Quantitative studies on the dispersal of skin bacteria into the air. J Med Microbiol. 1976;9:53–61.

    Article  CAS  PubMed  Google Scholar 

  35. Ferro AR, Kopperud RJ, Hildemann LM. Source strengths for indoor human activities that resuspend particulate matter. Environ Sci Technol. 2004;38:1759–64.

    Article  CAS  PubMed  Google Scholar 

  36. Johnson GR, Morawska L. The mechanism of breath aerosol formation. J Aerosol Med Pulm Drug Deliv. 2009;22:229–37.

    Article  PubMed  Google Scholar 

  37. Nicas M, Nazaroff WW, Hubbard A. Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens. J Occup Environ Hyg. 2005;2:143–54.

    Article  PubMed  Google Scholar 

  38. Wisconsin Department of Health Services from. https://www.dhs.wisconsin.gov/chemical/carbondioxide.htm.

Download references

Acknowledgements

Not applicable.

Associated context

Supporting information: Additional CO2 detection data for Sensor 1 and for multiple trials are included in the supporting information free of charge (PDF).

Funding

The authors’ have no funding to declare.

Author information

Authors and Affiliations

Authors

Contributions

The manuscript was written through the contributions of all authors. All authors have given approval to the final version of the manuscript.

Corresponding author

Correspondence to Gregory T. Carroll.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

GC and DK are employed by Aerobiotix, Inc., which develops, manufactures and sells air cleaning equipment, however, the equipment used in this study is not developed, manufactured or sold by Aerobiotix, Inc.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1:

 S1. Sensor 1, trial 1 (see Figure 1 for sensor 2 data): COconcentration as a function of occupation time for a single individual in an enclosed OR with no ventilation. S2. Sensor 2, trial 2: CO2 concentration as a function of occupation time for a single individual in an enclosed OR with no ventilation. S3. Sensor 1, Trial 2: CO2 concentration as a function of occupation time for a single individual in an enclosed OR with no ventilation. S4. Sensor 2, Trial 3: CO2 concentration as a function of occupation time for a single individual in an enclosed OR with no ventilation. S5. Sensor 1, Trial 3: CO2 concentration as a function of occupation time for a single individual in an enclosed OR with no ventilation. S6. Sensor 1: When an individual enters an enclosed room containing normal OR airflow conditions (positive pressure of 0.03 in. H2O and a ventilation system operating at 20 ACH), CO2 exhalation can be detected provided that the individual is moderately active. S7. Sensor 1 data: The amount of detected CO2 increases over a 20-minute period when individuals are present in an OR with an air circulation system operating at a level of approximately 20 ACH and a positive pressure of 0.03 in. H2O.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Carroll, G.T., Kirschman, D.L. & Mammana, A. Increased CO2 levels in the operating room correlate with the number of healthcare workers present: an imperative for intentional crowd control. Patient Saf Surg 16, 35 (2022). https://doi.org/10.1186/s13037-022-00343-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13037-022-00343-8

Keywords